It is fed by a 2 pole 15a circuit breaker and uses 14 2 cable.
Ontario electrical code kitchen receptacles.
The revisions address ground fault circuit interrupter protection lighting and appliance requirements placement of kitchen receptacles and more.
Each fixed kitchen island or peninsula larger than 600m x 300m requires at least one outlet 15a split or 20a t slot.
However this requirement predates the requirement for counter receptacles and circuits.
A 20 amp receptacle is designed to accept the special plug on heavier use appliances and if such an appliance plugs into a 15 amp circuit there is a danger of drawing too much power and.
Receptacles in a kitchen used to serve counter tops should be supplied with at least two 20 amp branch circuits for small appliances.
Understanding the kitchen split receptacle circuit.
Methods of wiring a home may be used but must meet the canadian electrical code.
The ontario electrical code requires that all branch circuits supplying 120volt single phase 15 ampere outlets.
In addition to the nec code recommendations local building departments have their own code rules and these are the rules that must be followed for any house in the department s jurisdiction.
Kitchen wall not counter receptacles 2015 code separate branch circuit required 2018 code separate branch circuit not required wall receptacles provided in a kitchen are required to be supplied by a separate circuit.
Outlets must be no more than 1 8m apart measured along the wall behind a counter top and no more than 900m from a sink stove or end point.
Electricians contractors and other industry professionals.
This guide is meant to assist users and every effort has been made to ensure it reflects the current code however where discrepancies between this and.
Most of it however originates from people who work in the field.
A public input was received by nec code making panel 2 cmp 2 on the number of receptacle outlets for kitchen island locations in a dwelling unit.
No more than 12 outlets should be on a branch circuit.
There is no danger to installing 15 amp outlet receptacles on a 20 amp circuit in fact this is the standard practice but under no circumstances should a 20 amp receptacle be installed on a 15 amp circuit.
This request was made on behalf of a well known electrical labor association.
Electrical code basics and recommended practices for kitchen renovation often seem like pointless rules cooked up in an office boardroom as electrical code eventually does get hammered out across conference tables.
Trish what you have is actually a perfectly normal situation which meets the code rules in many electrical jurisdictions.